System monitoring

System monitoring

Elements of the system monitoring, such as vacuum switches and pressure switches, control the vacuum system.

Electronic vacuum switch - inline

  • For monitoring vacuum lines and circuits
  • Optimisation of cycle times and thus improvement of the economic efficiency of vacuum systems
  • Simple installation directly in the hose line
  • Compact, lightweight and robust design
  • One digital switching point and simple 2 LED display

Item no. GS02.006 GS02.008 GS02.010
Measuring range [bar (inHg)] -1 - 0 (-29.5 - 0) -1 - 0 (-29.5 - 0) -1 - 0 (-29.5 - 0)
Electric connection Plug connector M8x1, 4-pin Plug connector M8x1, 4-pin Plug connector M8x1, 4-pin
Pipe connection [mm] 6 8 10
Mounting position any any any
Operating voltage [VDC] 9 - 30 9 - 30 9 - 30
Own power consumption < 25 mA < 25 mA < 25 mA
Short-circuit protection yes yes yes
Reverse polarity protection yes yes yes
Switching output 1x PNP 1x PNP 1x PNP
Switching logic NO (NC on request) NO (NC on request) NO (NC on request)
Hysteresis ca. 5 % F.S. ca. 5 % F.S. ca. 5 % F.S.
Max. Output current max. 100 mA max. 100 mA max. 100 mA
Voltage at the output ca. Ub -1.5 V ca. Ub -1.5 V ca. Ub -1.5 V
Repeat accuracy ± 3% F.S. ± 3% F.S. ± 3% F.S.
Operating temperature [°C (°F)] -10 - 60 (14 - 140) -10 - 60 (14 - 140) -10 - 60 (14 - 140)
Medium Filtered, dry / lubricated compressed air, neutral gases Filtered, dry / lubricated compressed air, neutral gases Filtered, dry / lubricated compressed air, neutral gases
Protection class IP40 IP40 IP40
Storage temperature [°C (°F)] -20 - 85 (-4 - 185) -20 - 85 (-4 - 185) -20 - 85 (-4 - 185)
Weight [g] 20 30 30

Vacuum switch – electromechanical

  • An electrical signal is triggered when set vacuum value is reached
  • Switching point set via setscrew
  • Hysteresis is fixed
  • Standard vacuum connnection via galvanized steel G1/8 screw-in port
  • Long service life due to high quality, robust design
  • Can be mounted in any position

Pneumatic vacuum switch, regulation range - 150 to - 950 mbar

  • Switch outputs a pneumatic signal when the set vacuum level is reached
  • No electrical connection required
  • Usable as switch element for pneumatic valves

Mini vacuum switch – electronic with digital output

  • Switch outputs a digital signal when a specific vacuum level is reached
  • Vacuum level is manually set with a potentiometer screw
  • Hysteresis is fixed
  • Red LED indicates set level reached
  • Space-saving installation on ejectors thanks to very small design
  • Included in scope of delivery: cable 1.5 m, 3-pole, open wire

Electronic vacuum switch measuring range 0 to -1 bar

  • Monitoring of vacuum levels, e.g. in handling systems
  • Intelligent sensor with "teaching" feature
  • Suitable for all vacuum levels due to flexible setting of switching point and hysteresis
  • Small and robust
  • Easy operation
  • Protection class IP65 (no ventilation tube required)
  • Flexible mounting: Control panel can be rotated 360° after installation

Vacuum switch electronic, with two digital outputs and display

  • Monitoring of vacuum levels, e.g. in handling systems
  • Optimization of cycle times to improve the economy of vacuum systems
  • Two freely adjustable digital outputs to set lower and upper threshold values
  • Additional analog output
  • 7-segment LED-display
  • Protection class IP65 (no ventilation tube required)
  • Integrated reverse voltage protection
  • Compact, lightweight and robust design
  • Flexible mounting: GS.001 can be rotated 360° after installation